Page view 107
Technician’s Handbook
98
"External Busy" on
Sx200 Set calling
another Sx200
Or "Xnet Busy" on
3300 Set calling a
Sx200 (con’t)
Incorrect IP node
Number or IP address
IP trunks use IP
addresses to find call
route destinations. In
both the local and
remote IP node, the
remote IP node IP
address must match
the IP node number
specified in Form 48
and the Form 23 sub
form . On MN3300 the
PBX number is the IP
node number on
SX-200
Incorrect programming
of Form 22: Modified
Digit Table
Check Form 22 and
delete or add the digits
as required for the
specific route number
identified in Form 23
Incorrect COS options Enable Options
801,802,811 in Form 3
Busy tone before you
finish dialing digits.
Only dialed the
displayed digits.
Form 26 has the wrong
ARS digit strings
programmed
Check the ARS digit
strings in Form 26
Silence after Dial all
digits, then got busy
tone. All dialed digits
displayed
Incorrect COS options Enable Options
801,802,811 in Form 3
Table 15: SX-200 IP Node Troubleshooting Table (Continued)