Mitel Panther II 820 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
Installation
A. Behind a PABX or Electronic Key System
B. Behind Centrex Telephone Lines
Note: Use ground start lines for fastest call processing.
Programming
Connect the ACA-1A to an analog PABX/KSU or OPX station.
C.O. Lines
Analog PABX/KSU or OPX station
Extensions
Rear view of the ACA-1A
120V AC
PROTOCOLS
1 2 3 4
CO/PABX
LINE
USE ONLY LISTED
CLASS 2 POWER SOURCE
12V
O.5 A MAX
Rear View of the ACA-1A
120V AC
Centrex Telephone Line
PROTOCOLS
1 2 3 4
CO/PABX
LINE
USE ONLY LISTED
CLASS 2 POWER SOURCE
12V
O.5 A MAX
B. Accessing the Programming Mode
1. From a Touch Tone phone, call the line attached to the ACA-1A.
2. When the ACA-1A answers, enter a “Q”.
3. When the recording stops, enter the six digit security code (see section A).
4. To leave the programming mode, simply hang-up. The ACA-1A will time out after 20 seconds and disconnect.
Standard carbon handset
(not included)
Viking Model W-3610
VIKING
©
AUTOMATED ATTENDANT
MODEL ACA-1A
REC/MON
TAPE
LED
VOL
PLAY REC
START
A. Security Code (memory location #47)
The security code allows the ACA-1A to be programmed remotely. The factory set code is 845464 (V-I-K-I-N-G). It
is recommended that the security code be changed after installation.
Note: The security code must have six digits and cannot contain a Q or #
.
C. Speed dial numbers
Up to 10 speed dial memory locations can be programmed ((9) 16 digit, (1) 32 digit).
Note: Special characters such as Q’s, #’s and pauses require 1 digit (see section J. Programming Features).
• To protect the micro-processor and provide maximum efficiency, the installation of a surge protector is recommended.
• The ACA-1A uses non-volatile message storage. In the event of a power loss, the messages and programming will be
retained indefinitely. For applications requiring full operation during power failures, use a commercially available
uninterruptable power source (UPS).
Start Button
Play/Record Switch
Playback Volume Control
Status Indicator
Tape Input
Page view 2
1 2 3 4 5 6

Comments to this Manuals

No comments