Routine Maintenance
183
Routine
Maintenance
4. Set all options to match those on the SX-2000 Feature
Options Record sheet that was shipped with the software
(X = YES).
5. Select the machine configuration FD2 and set the
maximum number of cabinets to 12.
6. Press the <generate> softkey, then press the <bottom>
softkey.
7. Enter the MITEL options password (from the SX-2000
Feature Options Record sheet received with the
software); press the <commit> softkey, then press the
<confirm> softkey.
This message appears:
Changes committed. ** Reload the system to make new values
effective. **
8. Quit the form.
9. Hold down PANEL ENABLE and press the inactive
plane’s RESET button.
10.Log on to the inactive plane and enter:
PARTITION.
11.Go to Restore the Database to the Inactive Plane on
page 183.
Restore the Database to the Inactive Plane
1. Insert the datasave RSD in the RSD drive.
2. Log on to the inactive plane and select maintenance
mode.
3. Enter:
VOL MOUNT RSD
Read the volume name of the RSD from the system
response on the maintenance terminal.
If the Data Save was created before Q26.13.1, the RSD will
be mounted as “read-only”.