Typical Configurations
39
Compression
channels
64 192 G.729a compression is not a standard offering on base
systems. Additional DSP resources are needed to achieve
the values shown. Compression is added in block of 8
bi-directional channels on Quad DSP modules and DSP II
modules only.
T. 38 16
Record-a-Call 12 Every Record-a-Call session uses a conference resource and
a voice mail session from the available pool. The maximum
number of simultaneous sessions supported is 12, but may be
limited to less than this by the available resources.
CIM ports 4 (12) These ports may be used to connect ASU cabinets only. Up
to 2 Quad CIM cards can be installed to increase the number
of CIM ports.
Analog trunks 36 96
ASUs supported 4 (12) Additional ASU cabinets may be connected to the Quad CIM
cards.
LS trunks (in ASU) 22 (38) The internal ASU (AMB) has 6 LS trunks and up to four
Universal ASU cabinets may be added with 4 LS trunks each
(or four ASU II cabinets with 8 LS trunks each).
IP networking yes The system can support a maximum of 2000 programmed IP
trunks, but the number which can be used at any one time will
be limited by other resources.
MMC modules
(installed slots)
Echo Canceller (3,4,5,6)
Quad DSP (3,4,5,6)
DSP II (4,5,6)
Dual FIM (1,2,3,4)
T1/E1 (1,2,3,4)
Quad BRI (1,2,3,4)
Quad CIM (1,2,3,4)
The maximum number of usable framer and FIM modules
may be limited by the E2T capacity of the system, especially
in the base configuration (single processor).
Digital links 16 Digital trunks may be on embedded Quad BRI modules (12),
Dual T1/E1 modules (8), T1/E1 combo modules (4), or
external NSU cabinets (16).
Peripheral cabinets 6 (+6 expanded) The number of peripheral cabinets may be doubled by using
an expanded peripheral cabinet, but this will only increase the
line size and does not increase the traffic capacity.
NSU/DSU cabinets 8 To install the maximum number of NSUs and peripheral
cabinets at the same time will require chaining of the NSUs.
Note that the maximum usable capacity may be limited by the
E2T and DSP resources before the physical capacity is
reached.