Routine maintenance
123
Maintenance
Routine
12. After you click Reboot the 3100 ICP, the power
indicator turns red for about 30 seconds.
13. Restore your database. Restoring the
database/software and database (p. 154).
Applying a software patch
A software patch is used to fix a problem in the software.
Software patches are posted on the Mitel Online site.
To apply a software patch
1. Download the patch from Mitel Online to a PC on the
LAN.
2. Launch the system tool.
3. Choose System from the Selection menu.
4. Click Apply Patch.
5. Read the instructions and then click Proceed.
6. Click Browse and then navigate to the patch file
(.maz) on your PC
7. Select the file, click Open and then click OK.
8. After the files have been copied to the system the
message “Operation Successful” is displayed
9. Reboot the system. See Rebooting the system (p.
116).
Replacing a flash card
Do not proceed with this procedure until you have
obtained the Mitel Option System Selection
password for the system. This procedure takes the
system out of service for approximately 60 minutes.
You replace a flash card to install a new release of
software (for example: from Release 2.3 to Release 3.0)
onto the system. Note that the flash card does not include
the voice mail prompts.