96
SX-200 ICP MX Technician’s Handbook
Programming Embedded Voice Mail
CDE Programming for Embedded Voice Mail
The default database includes most of the programming required for a fully
operational voice mail system. The defaults are as follows:
16 Voice Mail mailboxes are assigned with the same extension
numbers as the first 16 IP phones (extension 102 to 117)
- Attendant Console (SUPERCONSOLE 1000; extension 198)
- Subattendant (extension 199)
- Two ONS ports (extensions 201 and 202)
Hunt Group for Voice Mail ports with pilot number 300
- COS 6 and
- extension 301 to 324 for voice mail ports (default is from 301 to 304)
System-wide Call Forward No Answer to voice mail, for internal and
external calls
Maximum number of saved messages per mailbox is 10, which the
system deletes after 15 days.
Voice mail programming that is NOT provided in the default database
includes:
Auto Attendant Setup
Bilingual Prompting
Mailbox Greetings and Names
Distribution Lists
RAD Setup
Record a Call
PMS Integration
Note: Embedded voice mail Release 6.22 (included in SX-200 ICP Releases
2.0 and 2.1) now supports notification on every new message regardless of
whether or not notification for previous messages has already been
answered. This feature is normally deactivated by default and may only be
enabled or disabled by accessing the Administrator's mailbox.