SX-200 ICP MX Technician’s Handbook
In the Data Terminal Equipment profile (DTE) field, enter the DTE
number you used in Form 29 and the same CDN you used in Form 11.
- Assign a Tenant, Extension number, COS, COR, and circuit
descriptor number programmed in Form 11.
5. Program the RS232-to-IP serial port converter with the settings in
Table 24 on page 149.
6. Connect the Hotel/Motel terminal or ACD Monitor computer to the
Layer 2 switch using the RS232-to-IP serial port converter.
7. Verify that the device and SX-200 ICP are communicating. If they are
communicating, you will see an exchange of ENQ (Enquire) and ACK
(Acknowledge) commands at the device. If they are not
communicating, see page 271 for troubleshooting information.
Note: For Remote Port, enter the port number programmed in Form 12, not
6830 as the table shows.