Installing SX-200 Peripheral Cabinets
You can connect up to seven Peripheral Cabinets to the MX controller via
CIM or FIM cables. The peripheral cabinet types can be any mixture of SX-200
ELx, EL, ML or LIGHT.
FIM Connectivity
There are three variants of the FIM II modules.The same variant of fiber
interface module (1, 5, or 14 km) must be at both ends.
CIM Connectivity
There is only one variant of the CIM. In the peripheral cabinets, a CIM sits
on a Bay Control Card III (BCC III), on a Peripheral Interface Module
Carrier card, or on a PRI card.
The CIM (Copper Interface Module) supports a distance of up to 30
meters or 100 feet.
The CIM requires Category 5 UTP crossover cable (TX and RX pairs
reversed) with RJ45 connectors.