Mitel 50005070 Instruction Manual Page 193

  • Download
  • Add to my manuals
  • Print
  • Page
    / 416
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 192
183
Advanced Installation and Programming
SX-200 ICP Programming
1. Form 48, Voice Networking
- Enter the IP Node Number and IP Address of each IP-PBX and
specify the maximum number of calls allowed to each.
The example below shows the Form 48 programming for a network of
three IP-PBXs. Each IP-PBX (node) has a unique IP Node number that
all the other IP-PBXs must have in their programming. The local site is
always Bay 1; the other sites have no Bay association.
2. Form 03, COS Define
- Enable the following COS options
- 801, Incoming Trunk Call Rotary
- 802, Limited Wait For Dial Tone
- 811, ANI/DNI/CLASS Trunk
- It is also recommended that you enable COS option 702 to prevent
calls from being denied access to trunks when the SMDR output is
stopped. If you want to capture incoming SMDR, enable COS
options 806 and 814.
Notes:
1. MAX CALLS must be greater than zero (the default); otherwise,
no calls are allowed to the node.
2. Each IP-PBX in the network must be assigned a unique IP Node
Number, which can be any number in the range 1 - 255.
Note: COS number 7 has the default IP Trunk settings.