SX-200 ICP MX Technician’s Handbook
Installing the Optional Dual T1/E1 Framer Module(s)
The Dual T1/E1 Framer module has two digital trunk ports, each of which
can be programmed to support either T1/D4 or PRI. Up to two modules can
be installed in MMC slots 1 and 2 of the MX controller.
The system can support up to two Dual T1/E1 Framer Modules installed in
Module slots 1 and 2.
To install a Dual T1/E1 Framer Module:
1. Unplug the power cord from the controller.
2. Remove the top cover and the front panel (see page 37).
3. Insert the Dual T1/E1 Framer into Module slot 1 or 2 on the Main Board
connector.
4. Attach the screws.
5. Replace the front panel and the top cover.
6. Program the module in CDE:
- Assign the module a bay number in Form 53, Bay Location.
- Program the T1 link; see page 134.