Basic Programming
4. If you selected Ethernet Network Card, enter the IP Address of the
Remote Site.
If you selected Serial, select the connection name you entered when
you created the dial-up network connection.
5. For the Ethernet Remote System, select PRI Card / Universal NSU.
6. Click Connect.
IMAT displays a confirmation of the connection (for example
“Connected over Ethernet”).
7. Press Okay.
8. In the File menu, select Load -> Database -> Sources -> PRI Card
/NSU. This loads the IMAT with the database from the NSU.
9. Press Load.
IMAT provides a confirmation of the connection (for example
“Database received”).
10. Press Okay.
11. In the File menu, select Load -> SW Versions -> Sources -> PRI Card
/Universal NSU. This loads the IMAT with the Software version from
the NSU.
12. Press Load.
IMAT provides a confirmation of the connection (for example
“Software Version received”).
13. Press Okay.
14. Verify that the SW Version of the NSU matches the SW version listed
in the FCI delivered with the latest SX-200 ICP load:
- In the Maintenance menu, select Software versions. Verify the
package version that is listed against the FCI.
- If the package version and the FCI don't match, select SW Upgrade
From IMAT (the NSU load is on the CD).
- After the Upgrade is completed, select Remote Site Reset.
15. Program the NSU Config for the links provided by your PRI provider:
- In the Config menu, select Site Options.
- Confirm the System Type: Universal NSU.