Basic Programming
4. Form 12, Data Assignment
- Program a SOCKET type data device to an available PLID in the
following range:
PLID Port PLID Port
1/13/20 61320 1/13/25 61325
1/13/21 61321 1/13/26 61326
1/13/22 61322 1/13/27 61327
1/13/23 61323 1/13/28 61328
1/13/24 61324
- Assign a Tenant, Extension number, COS, COR, and circuit
descriptor number.
5. Form 34, Directed I/O: program the PMS.
6. Form 03, Class of Service Define
- Program the following table:
EXT NUM PRINTOUT PRINTOUT TYPE GUARANTEED
From Form 12 PMS AUTOPRINT NO
Device COS Option Status
Attendant
Consoles
101 Attendant Outgoing Restriction / Room Status
Set Up
ENABLE
105 Attendant Guest Room Key ENABLE
Room
Phones
202 Alarm Call ENABLE
220 Do Not Disturb ENABLE
232 Message Waiting SETUP Lamp ENABLE
703 Message Register Applies ENABLE
239 Priority Dial 0 (optional - see step 6) ENABLE
244 Room Status Applies DISABLE
608 SUPERSET Status Display DISABLE
Page view 162