Page view 163
154
SX-200 ICP MX Technician’s Handbook
7. Form 19, Call Rerouting
- Program “Station Dial 0" routing.
The “Station Dial 0" answer point for all tenants must be a Console
LDN or Subattendant LDN. To allow the customer’s PMS to set
message waiting, you must program Day, Night 1, and Night 2 answer
points to the same LDN.
- If you require different “Dial 0" answer points for Day, N1, and N2
use “Priority Dial 0" as an alternate method.
8. Form 34, Directed I/O: program the PMS.
9. Do one of the following:
- Start a Telnet session on the PMS computer to the IP address of the
SX-200 ICP and the socket port number programmed in Form 12.
- Connect the PMS computer to the Layer 2 switch using the
RS232-to-IP serial port converter. Then, program the converter
with the settings in Table 24 on page 149.
10. Verify that the customer’s PMS computer communicates with the
SX-200 ICP.
For serially-connected PMS computers, you will see an exchange of
ENQ (Enquire) and ACK (Acknowledge) commands at the customer’s
PMS computer if it is communicating with the SX-200 ICP. If they are
not communicating, see page 271 for troubleshooting information.
[ Tenant ___ ] Type Of Call Day N1 N2
Station Dial 0 Routing Same LDN Same LDN Same LDN
EXT NUM PRINTOUT PRINTOUT TYPE GUARANTEED
From Form 12 PMS AUTOPRINT NO
Note: For Remote Port, enter the port number programmed in Form 12, not
6830 as the table shows.