SX-200 ICP MX Technician’s Handbook
PRI Card Configuration Rules for SX-200 RM Cabinets
The PRI card requires a Stratum 3 clock MMC installed in the SX-200
ICP controller.
The peripheral cabinet supports one or two PRI cards in Slot 10 or 11.
The PRI card will appear as a peripheral bay on the SX-200 ICP
controller, and the two links of the T1/E1 module installed on the PRI
card will appear as slots 5 and 6 on that bay (not on the peripheral
cabinet).
The PRI card bay number is designated in Form 53.
The PRI card requires a FIM II or CIM to connect to the SX-200 ICP
controller.
The S1 switch settings on the PRI Card inform the T1 module of the
location of the clock source. Both switches must be set to closed as
indicated in the following illustration (to designate the interface module
as the clock source).
Inserting the PRI card in any other slot besides 10 or 11 will cause
the power supply to fail.