Mitel 50005070 Instruction Manual Page 84

  • Download
  • Add to my manuals
  • Print
  • Page
    / 416
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 83
74
SX-200 ICP MX Technician’s Handbook
Connecting Music on Hold, Paging
and Door Phone/Door Opener
Music-on-Hold (MOH) interface
The mini (1/8" - 3.5 mm) phono jack on the back panel of the SX-200 ICP
controller provides an interface to an external music source (radio, CD
player, etc.) for Music on Hold.
Input signals must be in the range of 10 to 100 mVrms. Any DC voltage
applied to the input must be less than 50 VDC.
CDE Programming
MOH requires no CDE programming in the default database. If a different
database is used, assign Music-on-Hold to PLID n/13/29/0 where “n” is the
IP Bay number (default 1) in Form 18.
Paging
The controller provides a single dedicated paging circuits for the
connection of customer-provided paging equipment. The equipment
connects to the DB-9 on the front of the controller. See Appendix C for
connector pinouts and relay states.
CDE Programming
The default database has programming for single zone paging to Zone 1,
which any station can access by dialing *12. No additional programming is
required.
If using a different database, complete the following programming:
1. In Form 18 (Miscellaneous System Ports), program a paging device.
2. Enable COS Option 303 (Paging Zone 1 Access) in the Class of Service
of each extension that requires access to the paging equipment.
Note: Powering down the SX-200 ICP redirects the MOH source to the paging
output. To stop the music from being heard over the pager, power down both
the MOH source and paging amplifier before powering down the controller.