Basic Programming
System Options to Avoid
Certain options in Form 04 could cause unexpected behaviors in system
operation if changed from their factory-set (default) values.
Programming the Customer Data Entry
(CDE) Forms
The CDE Forms are factory-set with default values that make programming
the system faster and easier. The defaults allow you to install the system
and connect up to 20 IP phones plus two analog terminals (phone, fax, or
modem) and place extension-to-extension calls without doing any
programming. You will also be able to receive fax and modem calls, but will
have to program ARS to make external calls from ONS devices.
The default database configures the system to operate as a square key
system with six trunk appearances per phone.
Table 13: System Options to Avoid
Option # Option Name Default
60 Tone Plan NA
68 SX-200 ICP DSP DTMF Receiver Channels
(0...7)
7
69 DTMF ON Timer (5-15 in 10 ms increments); 9 (90 ms)
70 DTMF OFF Timer (5-15 in 10 ms increments); 9 (90 ms)
71 Slot 10 FIM Capacity (2 or 3 Bays) 2
72 Slot 11 FIM Capacity (2 or 3 Bays) 2
Note: The default numbering plan uses three-digit extension numbers. If you
require a four-digit plan, either reprogram Forms 9, 17, and 50 or install the
four-digit database available on Mitel Online. For more information, see
“Installing an Alternate Database” on page 201.