Mitel 50005070 Instruction Manual Page 122

  • Download
  • Add to my manuals
  • Print
  • Page
    / 416
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 121
112
SX-200 ICP MX Technician’s Handbook
4. Press Auto Program.
The system prompts for an extension number to assign to the first
auto-programmed extension. The number is incremented by one for
each subsequent extension—for example, 100, 101, 102.
5. Enter a starting extension number.
Conflicts with existing extension numbers result in an error message
and a prompt to press the CONTINUE or ABORT softkey.
Auto-programming will not proceed to the next BAY/SLT/CCT until a
valid extension number has been found for the current position.
After verifying that the unprogrammed sets are physically connected,
the system automatically programs all unprogrammed circuits. The
system displays all of the devices that have been programmed.
If a circuit cannot be programmed because an extension number has
already been assigned to that circuit, a warning is displayed. Press
ABORT to cancel the procedure or press CONTINUE to skip the
device and resume programming the other devices in the range.
Deleting a Device and All Dependent
Resources
The DELETE softkey in Form 09, Desktop Device Assignments, deletes a
device and all of its dependent resources including
All line keys (including LDN) that are programmed on a deleted set,
standalone BLF, or PKM module
All line and feature keys that are programmed on associated BLF or
PKM modules
The associated BLF and PKM modules
Any other line appearances and BLFs of the deleted station or set.
A warning message appears if any of the above exists. To continue, press
CONFRIM. To abort, press CANCEL.
Note: The maximum length of extension numbers is five. It is recommended
that the length be equal to the “Length of Mailbox Numbers” in Form 49, to
take advantage of automatic mailbox creation.