111
Basic Programming
Programming Stations/Sets Automatically
The AUTO PROGRAM function in Form 09, Desktop Device Assignments,
checks for unprogrammed circuits in the system and programs them as
follows:
• Extension numbers are automatically assigned according to a Bay, Slot,
Circuit address format “BSCC”, where
- B is the Bay number (1-8)
- S is the slot number (1-8)
- CC is the cct number (01-12).
The system prompts for a starting extension number.
• Other parameters assigned to ONS and OPS devices:
- COS = 2
- COR = 1
- Tenant = 1
• Other parameters assigned to DNIC and IP sets:
- COS = 1
- COR = 4 for all set types except SUPERSET 430 and
SUPERSET 4150
- COR = 5 for the SUPERSET 430 and SUPERSET 4150
- Tenant = 1
To automatically program all connected sets, DNIC sets and DMPs:
1. Install all ONS cards, OPS cards, DNIC cards. Do not program stations,
DNIC, sets or DMPs.
2. Connect the DNIC sets or DMPs to the circuits.
3. Access Form 09, Desktop Device Assignments.
Note: Before an extension number can be automatically assigned, a DNIC
set or DMP must be physically connected to the circuit. If no set or console
is detected on a circuit, that circuit is skipped and no extension number is
assigned.
Comments to this Manuals