129
Basic Programming
Programming an Embedded PRI Trunk
1. Form 53, Bay Location Assignment
- Assign the Dual T1/E1 Framer module a bay number.
2. Form 1, System Configuration
- Program the node type as ONB T1 NODE. Program the trunk card
as T1 ISDN for the slots specified in the following table.
Module Location Slot
MMC1 2 and/or 4
MMC2 6 and/or 8
3. Form 03, Class of Service (COS)
- Create a separate COS for ISDN trunks.
- Enable the following COS options for the ISDN Trunks:
246 – SMDR- Extended Record
701 –No Dial Tone
702 –SMDR - Overwrite Buffer. (Required if option 806 SMDR-
Record Incoming Calls enabled)
801 –Incoming Trunk Call Rotary
802 –Limited Wait for Dial Tone
811 –ANI/DNIS Trunk
814 –SMDR - Record ANI/DNIS
Note: Reset the system after updating Form 53.
Note: One link of the Dual T1/E1 Framer can be programmed for PRI (T1
ISDN) and the other for T1 (T1 Trunk).
Note: A trunk must be programmed in form 14 or 15 before it the will show
as installed in Form 1.
Note: COS Level 7 in the default database has all COS options required by
ISDN trunks enabled except for Option 246 (SMDR - Extended Record).
Tip: Ensure that COS Option 800 (ANI Applies) is NOT enabled in the class
of service of the ISDN trunks.