SX-200 ICP MX Technician’s Handbook
Launching the IP Phone Analyzer
1. Click Start on the Windows taskbar.
2. Point to Programs.
3. Click Mitel IP Phone Analyzer.
For detailed information on using the IP Phone Analyzer, refer to its Online
Help.
Enabling Tool Analysis
From the IP Phone Analyzer Tool:
1. Select Commands, and then Register Set.
2. Enter the IP address of the IP phone.
From the IP phone:
Reboot the phone (by removing and restoring power) to add the IP
address of the PC to the phone.
The IP address will appear in the IP Phone Analyzer Status View
window.
The phone will be out of service while it resets.
Disabling Tool Analysis
From the PC hosting the Analyzer Tool:
Access the Status View window, left-click on the IP address,
right-click, and then select Delete.
From the CDE/Maintenance Terminal:
In Form 47 (DHCP Parameters), delete Option 131 to disable IP
messaging to the Analyzer Tool.
There will be a service outage while the phones reset.
From the IP phone:
Restart the set to clear PC’s IP address from the phone.