SX-200 ICP MX Technician’s Handbook
To install an ASU II:
1. Mount the ASU II.
2. Connect a cross-over Category 5 cable with RJ-45 connector to the
CIM port on the ASU II and a free CIM port on the controller.
3. Complete telephony cabling for the ASU II. See Appendix C for ASU II
connector pinout.
4. Connect power to the ASU II.
5. Wait for the CIM LEDs to turn on indicating that the CIM link is
synchronized.
6. Program the ASU II in CDE.
CDE Programming
1. In Form 53 (Bay Location Assignment)
- Assign a bay number to the CIM ports used to connect the ASU II
to the controller.
2. In Form 01 (System Configuration)
- Program the bays assigned in Form 53 as node type ASU BAY.
- Configure the card(s) in slot 1 and 2 only.
3. For ONS devices, complete the remaining CDE programming for the
cards. See “Programming a Single Line Voice Station” on page 114.
4. Program LS trunk devices in CDE Form 14 (Non-Dial-In Trunk) or CDE
Form 15 (Dial-In Trunks).
Note: The ASU II can be located up to 30 meters (100 feet) away
from the SX-200 ICP