Mitel 50005070 Instruction Manual Page 281

  • Download
  • Add to my manuals
  • Print
  • Page
    / 416
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 280
271
Basic Troubleshooting and Repair
SX-200 ICP and PMS Cannot Communicate
If the SX-200 ICP PMS interface and the customer’s PMS computer
cannot communicate, the system will generate PMS related maintenance
log messages. Typically, PMS maintenance log messages will identify
Operating status of the PMS
Invalid start (STX) and end (ETX) of text message characters
Invalid function code message characters
Invalid status code message characters
Invalid room number message characters.
Testing the PMS Interface of the PBX
PMS problems typically occur in these areas:
PMS Protocol settings: Ensure that the communication parameters
between the systems match.
PMS Programming: Verify that all the recommended PMS and
Dataset programming is complete.
RS232-to-IP serial port converter: Use a straight-through cable
between the customer’s PMS computer and the converter.
Test the SX-200 ICP PMS interface as follows:
1. Disconnect the customer’s PMS computer from Ethernet-to-Serial
converter.
2. Connect a personal computer to the converter.
- Ensure that the communications parameters of the personal
computer / terminal match those expected by the PBX’s PMS
interface.
- Verify that you receive the ENQuire character from the SX-200 ICP
PMS interface. If not, verify that all the programming and the
connections are correct.